Layered membranes with interlayer spacing tuned from 1.39 to 152,000 nm shown in lab study
Authors report reversible control of interlayer spacing across five orders of magnitude via deprotonation of cellulose nanofibers and cation coordination, tested in laboratory devices.

A research team has reported a deprotonation–ion coordination strategy that sets the interlayer spacing of layered material membranes across five orders of magnitude, according to a paper available via doi.org nature.com
doi.orgnature.comOpen source ↗. The spacing ranges from 1.39 to 152,000 nm, and the change is reversible. The work was carried out on laboratory membrane samples, and the authors describe it as a single platform that can be customized for different devices.
How the interlayer spacing is controlled
Cellulose nanofibers are intercalated between the layers of the membrane. Deprotonation of these fibers produces electrostatic repulsion, which expands the interlayer spacing. Charge compensation through cation coordination makes the spacing tunable in the opposite direction, so the process is reversible.
Precise and reversible control of ion channel size is important for device performance, and the authors state that conventional approaches to channel regulation are limited in tunability, reversibility and precision. With this method, porosity of the membranes varies from 0% to 78%, and membrane thickness from 43 to 5,400 μm.
Effect on device performance
The authors tested the same membrane platform in three applications. A slight interlayer expansion to 1.48 nm raised zinc-ion capacitance by 67% relative to non-expanded membranes nature.com
doi.orgnature.comOpen source ↗. A 21,583-fold expansion, to about 30 μm, raised osmotic energy conversion power by 63%. A 100,719-fold expansion, to about 140 μm, enabled what the authors call exceptional pressure sensing.
The authors present the approach as a generalizable paradigm for nanometric microstructure engineering of various van der Waals materials. The results are laboratory demonstrations of membrane structure and of individual device metrics; the available text does not describe finished devices.