Science › Physics2 min read

Magnetic field cut laser-target EMPs to 0.32–0.65× at 1 GHz; picosecond shots saw 1.75× growth

In nanosecond laser–target experiments at 12 and 0.1 T, EMPs near 1 GHz fell; at about 10¹⁹ W/cm² with 6–10 T they rose. Such pulses can disrupt measurements and damage equipment.

Magnetic field cut laser-target EMPs to 0.32–0.65× at 1 GHz; picosecond shots saw 1.75× growth
Photo: Lawrence Livermore National Security, Wikimedia Commons, CC BY-SA 3.0 · License: CC BY-SA 3.0

Researchers reported in High Power Laser Science and Engineering that an applied magnetic field changes the electromagnetic pulses (EMPs) produced when a laser strikes a target. With nanosecond pulses, the field reduced EMPs in the band near 1 GHz by factors of 0.65 and 0.32 in two experiments. With picosecond pulses at about 10¹⁹ W/cm² and fields of 6–10 T, EMP magnitude instead increased by a factor of 1.75 cambridge.orgHigh Power Laser Science and Engineeringcambridge.orgOpen source ↗. Laser–target EMPs can interfere with measurements and damage equipment.

Nanosecond pulses: suppression near 1 GHz

The two nanosecond experiments differed in geometry (spherical and planar), laser intensity (about 10¹³ and 10¹⁵ W/cm²) and applied field (12 and 0.1 T). Both showed suppression of EMPs in approximately the 1 GHz band, by factors of 0.65 and 0.32 respectively.

According to the publication's retelling, the spherical experiments were capsule implosions at the OMEGA facility with 60 beams and 10–25 kJ, in fields of 10–12 T. The planar experiments used copper targets at the UCLA Phoenix laser facility with 16 ns pulses of 1–4 J and a field of about 0.1 T, over 400 shots. In the OMEGA shots, hard X-ray signals rose as EMPs fell. The authors link this to hot electrons being reflected back into the target, which neutralizes its charge. At UCLA the intensities were too low for hot electrons, and the authors concluded that the field restrained the sideways expansion of the plasma plume.

Picosecond pulses: enhancement

At high intensity the effect reversed. In planar experiments with a picosecond pulse at about 10¹⁹ W/cm² and fields of 6–10 T, EMP magnitude grew by a factor of 1.75 cambridge.orgHigh Power Laser Science and Engineeringcambridge.orgOpen source ↗.

These tests were done on the OMEGA EP laser with 10 ps pulses at 10¹⁸–10¹⁹ W/cm². Targets were 20 µm gold disks irradiated with 880–900 J, and 30 µm plastic disks irradiated with 200 J. Integrated spectral power below 1 GHz rose by about 75% relative to unmagnetized shots. The authors note that the stopping ranges of 1 MeV electrons are 402 µm in gold and 4600 µm in plastic, far larger than the foil thicknesses.

Sources · 2

Found a mistake?
  1. ↩
RealTech on TelegramSubscribe

Read also

Up next

The next story opens automatically

More
Follow us

Type at least two letters — results appear instantly

↑↓to choose↵to openescto close