Meta-analysis of 185 studies quantifies biomimetic building strategies across climate zones
A review of 185 peer-reviewed studies found mean gains of 145.6% in strength and 875.6% in toughness for bio-inspired building materials. Evidence is concentrated in temperate climates.

A systematic review and meta-analysis, described by Nexus, synthesized 185 peer-reviewed studies on biomimetic strategies in buildings. It compares their effect on structural safety, occupant comfort and energy efficiency across climate zones and application hierarchies. sciencedirect.com
Nexussciencedirect.comOpen source ↗ Studies were drawn from Web of Science, Scopus and PubMed and published between 1 January 2016 and 1 October 2025.
The authors note that the performance effects of such strategies across climates had been poorly understood. The review is intended as an evidence-based map for choosing a strategy for a given project context.
Where the evidence is concentrated
Research entries are concentrated in temperate climate zones (59.6%) and in the material hierarchy (62.2%). Applications were divided into three hierarchies: building configurations, material strategies and device-related implementations. Climate zones followed the Köppen-Geiger classification, 18 in total. Temperate entries were mostly in humid subtropical and oceanic regions such as Sydney, Hong Kong and Nanjing.
The concentration is strongest in structural safety, where studies focus on strength and toughness. For occupant comfort, research priorities vary with climate and occupant requirements, and heterogeneous indicators limit comparison of results. sciencedirect.com
Nexussciencedirect.comOpen source ↗
Strength, toughness and energy loads
Mean improvements are 145.6% in strength and 875.6% in toughness. In temperate climates the means are 110.7% ± 41.9% and 708.0% ± 444.8%. In arid climates they are 48.6% ± 12.1% for strength and 72.2% ± 38.1% for toughness, with an emphasis on waterproofing and moisture preservation. Among individual examples, DNA-inspired high-rise configurations reduced inter-story drift ratios by 16.54% to 59.20% under lateral loads, and lotus-leaf microstructures gave water contact angles above 167 degrees.
For energy efficiency, material strategies reduce cooling load by 34.0% on average and total load by 29.5%. Daytime cooling varies by climate zone; in temperate climates, which have the largest evidence base, the mean reduction is 9.29 °C ± 4.16 °C. The authors report that configurations also show considerable energy-saving potential, and that the review identifies gaps and development priorities, including validation in complete buildings.