MIPT system builds personal 3D left atrium models with fiber orientation from CT of six patients
A MIPT computational system reconstructs muscle fiber orientation across the full atrial wall thickness; so far it has been tested on six CT-based models.

Researchers at MIPT have developed a computational system that builds personal 3D models of the left atrium and reconstructs muscle fiber orientation through the full thickness of the wall. The system is based on high-resolution clinical CT scans of six patients with atrial fibrillation, according to Poisk. poisknews.ru
Поискpoisknews.ruOpen source ↗ So far it has been tested only on these six models.
Why fiber orientation matters
In atrial fibrillation, electrical signals spread chaotically through the atria, which raises the risk of stroke, heart failure and death. In computer models, a signal travels along muscle fibers much faster than across them, so fiber orientation matters.
It cannot be determined in a living patient with MRI: the atrial wall is only a few millimeters thick, and fibers can turn by 60–90° over 1–2 mm. For this reason, a fiber map taken from other people's hearts is transferred onto the patient's model. This smooths out differences between patients and depends strongly on how the landmark points are placed.
How the system works and what the calculations showed
First, the scans are annotated and a volumetric mesh of the atrium is built. Then a universal atrial coordinate system is extended across the wall thickness: the Laplace equation is solved to obtain a continuous coordinate from the inner surface to the outer one. This coordinate is used to transfer fiber orientation from the atlas to the patient's model. poisknews.ru
Поискpoisknews.ruOpen source ↗
The researchers compared two ways of joining the epicardial and endocardial fibers: a linear one, where the direction changes gradually, and a threshold one, where it changes abruptly in the middle of the wall. The choice changes the moment tissue is activated. Near the left pulmonary veins and the left atrial appendage, the linear method activated tissue 2 ms later than the threshold one; on the anterior wall near the mitral valve, the threshold method lagged by 1.3 ms. The average shift was about 5 ms.
With careful placement of landmark points, fiber direction deviates by 1° on average; with looser placement, by up to 4°. The error of transferring fibers from the atlas to the patient model was about 29° on both wall surfaces. For the ventricles it is half as large, 15.4–18.8°. The authors attribute this to the thin wall and the sharp turn of the fibers.
The system can also work with MRI data, but its accuracy on lower-resolution clinical MRI remains to be assessed. Next, the researchers plan to compare the two methods at different strengths of fiber influence on signal speed, including in fibrosis, ischemia and under drugs that alter tissue conduction. Valeria Tsvelaya, head of the MIPT Laboratory of Experimental Medicine, hopes the open tools will help create systems that suggest to a physician which areas of the heart to ablate. poisknews.ru
Поискpoisknews.ruOpen source ↗