# Two 1:150-scale DTU 10 MW turbines in a wind tunnel: wake coupling depends on motion phase

- Published: 2026-11-16 16:18 UTC
- Section: Power & Energy › Energy
- Tags: floating wind turbine wake, aerodynamic damping, tandem turbines, DTU 10 MW model, surge motion, reduced frequency, wind tunnel experiment, wake recovery, Politecnico di Milano
- URL: https://realtech.media/news/rt-c19fc021d5a776a84154857b_two_1_150/

**In a wind tunnel test with scaled turbines in tandem, downstream aerodynamic damping and thrust depended on the relative phase of the surge motion of the two machines.**

![Two 1:150-scale DTU 10 MW turbines in a wind tunnel: wake coupling depends on motion phase](https://realtech.media/media/2026/11/c11741719b479d40.jpg)
*Untrakdrover, Wikimedia Commons, CC BY-SA 3.0*

Researchers tested two 1:150-scale models of the DTU 10 MW turbine in tandem in the atmospheric boundary layer test section of the Politecnico di Milano wind tunnel, according to a paper at doi.org. Both models performed prescribed harmonic surge motions, while the motion-reduced frequency (0.12–0.48) and the relative phase between the two motions were varied systematically [1]. The authors state that experimental evidence of wake–rotor coupling between several moving floating turbines had been lacking [1].

## Experiment setup

The downstream turbine, WT2, stood 5.75 rotor diameters behind the upstream one, WT1. Each model had a rotor diameter of 1.2 m and SD7032 airfoil blades. Both were mounted on robotic platforms with a parallel kinematic mechanism that produced the harmonic surge motion.

The inflow was uniform and low-turbulence, with an ambient turbulence intensity of about 2 percent and a reference hub-height wind speed of 4.9 m/s. Both turbines ran at a fixed collective blade pitch of zero degrees and constant rotational speeds, without active control. The upstream turbine rotated at 570 rpm, which gives a tip-speed ratio of 7.3 in the undisturbed flow. Configurations in which only one turbine moved were used to separate wake-induced and motion-induced contributions [1].

## Phase-dependent damping

The upstream turbine produced coherent wake velocity oscillations synchronized with the imposed surge motion, and their amplitude depended strongly on the reduced frequency [1]. When this modulated wake reached the moving downstream rotor, its aerodynamic response depended strongly on the relative phase of the two motions [1].

In-phase motion gave the largest oscillations of downstream thrust and the largest equivalent aerodynamic damping. Anti-phase motion reduced the thrust oscillation amplitude and brought the damping to approximately half that of the upstream turbine [1]. Across all investigated conditions, wake interaction reduced the aerodynamic damping of the downstream turbine relative to the upstream one [1].

At the higher reduced frequency of 0.48, the coherent wake pulsations also enhanced wake recovery and increased the power of the downstream turbine. At 0.12 these effects were weaker [1]. According to the authors, wake coupling between moving floating turbines is a phase-dependent interaction that affects aerodynamic loads, downstream energy capture and the effective aerodynamic damping of floating-turbine response [1].

## Sources

1. [doi.org](https://doi.org/10.5194/wes-11-4305-2026)
2. [bioengineer.org](https://bioengineer.org/floating-wind-turbine-wake-synchronization-substantially-alters-downstream-aerodynamic-damping)

---